CBQTR - NICKEL-CADMIUM SEALED CELL BATTERY

  • MSDS: CBQTR
  • Manufacturer: AVEX ELECTRONICS CORP
  • Product Name: NICKEL-CADMIUM SEALED CELL BATTERY
  • National Stock Number: 6140-01-227-4799
Product Identification

Product ID:NICKEL-CADMIUM SEALED CELL BATTERY
MSDS Date:08/17/1992
FSC:6140
NIIN:01-227-4799
MSDS Number: CBQTR

Responsible Party
AVEX ELECTRONICS CORP
1683 WINCHESTER ROAD
BENSALEM, PA 19020
US

Emergency Phone: 215-638-1515

Info Phone: 215-638-1515

Cage: 58414

Contractor
AVEX ELECTRONICS CORP
1026 BENSALEM, PA 19020-4510 US

Telephone: 215-638-1515

Cage: 58414

Ingredients

CADMIUM (SARA 313) (CERCLA)

CAS: 7440-43-9

RTECS: EU9800000

Fraction By Weight: 0-20%

OSHA PEL 0.2 MG/M3 DUST

ACGIH TLV: 0.01 MG/M3 DUST

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


CADMIUM HYDROXIDE

CAS: 21041-95-2

RTECS: EV1260000

OSHA PEL 0.05 MG/M3 (CD)

ACGIH TLV: 0.05 MG/M3 (CD)


CADMIUM OXIDE (SARA 302/313) (CERCLA)

CAS: 1306-19-0

RTECS: EV1925000

OSHA PEL 0.2 MG/M3 DUST (CD)

ACGIH TLV: 0.01 MG/M3 (CD)


NICKEL (SARA 313) (CERCLA)

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 15-35%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3


NICKEL (II) HYDROXIDE; (NICKEL HYDROXIDE) (SARA 313)

CAS: 12054-48-7

RTECS: QR7040000

OSHA PEL 1 MG/M3 (NI)

ACGIH TLV: 0.1 MG/M3 (NI)

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


1); (NICKEL OXIDE)

CAS: 1313-99-1

RTECS: QR8400000

OSHA PEL 1 MG/M3 (NI)

ACGIH TLV: 1 MG/M3 (NI)


LUNGS. CADMIUM OXIDE &

RTECS: 9999999ZZ


GROUP

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:NOT APPLICABLE FOR FINISHED PRODUCT
USED UNDER NORMAL CONDITIONS. IRRITATION OF NOSE & THROAT,
SWEATING, CHILLS, SHORTNESS OF BREATH, WEAKNESS, LOCAL DERMATITIS,
NAUSEA, COUGHING, CHEST PAINS.
Explanation of Carcinogenicity:CADMIUM:IARC MONOGRAPHS, SUPP, VOL 7, PG
139, 1987:GRP 2A. NTP 7TH ANNUAL RPT ON CARCINS, 1994:ANTIC TO BE
(SUPP DATA)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:RESPIRATORY SYSTEM DISORDERS,
PROSTATE DISORDERS, LIVER & KIDNEY DISORDERS.

First Aid

First Aid:INHALATION:REMOVE FROM EXPOSURE, SEE MD. INGESTION:INDUCE
VOMITING IF CONSCIOUS, SEE MD. SKIN:FLUSH W/WATER FOR 15 MINUTES.
SEE MD IF SYMPTOMS DEVELOP. EYES:FLUSH W/WATER FOR AT LEAST 15
MINUTES. SEE MD IF SYMPTOMS DEVELOP.

Fire Fighting

Extinguishing Media:DRY CHEMICAL, CO*2, WATER.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .

Accidental Release

Spill Release Procedures:CONTAIN SPILL. COLLECT SPILLED MATERIAL &
PLACE IT IN PLASTIC-LINED CONTAINER. HEPA VACUUMING IS PREFERRED.
FLUSH SPILL AREA W/WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED, AVOID CONTACT
W/CLOTHING, AVOID GENERATING DUST.
Other Precautions:KEEP FOOD & TOBACCO AWAY FROM WORK AREA.

Exposure Controls

Respiratory Protection:WEAR NIOSH/MSHA APPROVED DUST MASKS OR
RESPIRATORS.
Ventilation:LOCAL EXHAUST &/OR MEECHANICAL (GENERAL) VENTILATION.
MAINTAIN OSHA PEL.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . WEAR COVERALLS.
Work Hygienic Practices:SHOWER & CHANGE. DO NOT WEAR CONTAMINATED
CLOTHING HOME.
Supplemental Safety and Health
EXPLAN OF CARCIN:CARCIN. HUMAN:LUNG, PROSTATE, RENAL SYS EFTS.
NICKEL:IARC MONOGRAPHS ON EVAL OF CARCIN RISK OF CHEMS TO MAN, VOL
49, PG 257, 1990:GRP 2B. NTP 7TH ANNUAL RPT ON CARCINS, 1994:ANTIC
TO BE CARCIN. HUMAN:LUNGS, NASAL CAVITIES.NICKEL OXIDE & NICKEL
HYDROXIDE:NTP 7TH ANNUAL RPT ON CARCINS, 1994:ANTIC(ING 7)

Chemical Properties

HCC:T6
Spec Gravity:1.6 (H*2O=1)
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:AVOID SHORTING. USE ONLY APPROVED CHARGING
METHODS.
Hazardous Decomposition Products:METAL OXIDE FUMES MAY BE EVOLVED AT
TEMPERATURES ABOVE MELTING POINT.
Conditions to Avoid Polymerization:DO NOT PUNCTURE BATTERY CASE.

Disposal

Waste Disposal Methods:DISPOSE I/A/W FEDERAL, STATE & LOCAL LAWS. IF
DISCARDED, TREAT AS HAZARDOUS WASTE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.